As a switchgear components supplier who has spent over a decade troubleshooting on-site issues with clients ranging from industrial plants to data centers, I’ve seen firsthand how even minor electromagnetic interference (EMI) can derail operations that rely on consistent, unbroken power. Last year, I received a frantic call from a manufacturing client in the Midwest—their 10kV switchgear panel had been acting erratically: protective relays would trigger false trips, their SCADA system would glitch, and sometimes, the entire system would reset without warning. We traced the root cause to a single, overlooked EMI issue in their busbar connections, and it cost them three days of production. That moment drove home that EMI isn’t just a technical buzzword; it’s a tangible, costly problem that every switchgear owner and supplier needs to address. Switchgear Components

EMI in switchgear components happens when electromagnetic fields from one part of the equipment disrupt the performance of adjacent or connected parts, or even external systems. Unlike high-voltage arcing that many are trained to spot, EMI is often subtle at first, manifesting as intermittent glitches instead of outright failures. But make no mistake—unaddressed, it can lead to critical safety risks, unplanned downtime, and compliance failures with standards like IEC 62271, which governs switchgear design. Let’s break down the most common EMI issues across key switchgear components, and what every operator should watch for.
First, busbars are the backbone of any switchgear assembly—they carry heavy AC or DC currents between incoming lines, circuit breakers, and distribution equipment. When busbars carry large alternating currents (especially at frequencies above 50Hz), they generate significant magnetic fields around them. If busbars are routed too close to sensitive components like control relays, PLC inputs, or communication cables, those fields induce electrical currents in the smaller, unshielded circuits. A classic example is a client of ours last year who installed their busbars just 10cm away from their low-voltage control cables. The 1000A current in the busbars induced a 120mV signal in the control wires—enough to trigger a false “overcurrent” trip in their protective relay. The fix wasn’t expensive: we re-routed the busbars to maintain a 30cm clearance and added a simple shielded cable for the control circuit, and the glitches stopped immediately. Even DC busbars, which generate static magnetic fields, can be problematic if they run alongside low-voltage signals; those static fields can interfere with sensor readings, causing inaccuracies in temperature or current monitoring.
Next, circuit breakers and contactors—critical for interrupting fault currents and switching loads—are major EMI contributors. When a breaker’s contacts open or close, they create rapid changes in current, which generate high-frequency transients (sometimes called “spikes”) in the electromagnetic spectrum. These transients can travel through the switchgear’s internal wiring or leak out into the surrounding space. We recently worked with a data center client whose 480V circuit breakers were causing EMI that disrupted their nearby network switches. The transients were coupling through the switchgear’s metal enclosure—while the enclosure provides some shielding, gaps around access panels or cable glands act as antennas, letting EMI escape. Even minor gaps, just a few millimeters wide, can emit enough high-frequency radiation to disrupt electronic equipment within a 50-meter radius. Another issue with breakers is their control coils: if the coil wiring isn’t properly shielded, the high inrush current when the coil activates can generate a magnetic field that disrupts adjacent sensors. We’ve solved this many times by adding ferrite cores to control coil leads—a simple, cost-effective modification that absorbs high-frequency transients before they can spread.
Insulators and busbar supports, which hold conductors in place, are often overlooked as EMI sources, but their design can play a big role too. Most insulators are made of non-conductive materials like epoxy or porcelain, but if they have surface contamination (dust, moisture, or oil residue), their surface can develop a conductive layer. This layer can create unintended capacitive coupling between busbars and adjacent components, allowing EMI to transfer more easily. Last quarter, a food processing plant reached out to us complaining that their motor control center (MCC) was causing their conveyor belt PLC to error. We inspected the insulators and found a thin layer of flour residue on their surfaces—flour is a conductive dust, and it had created a capacitive path between the high-voltage busbars and the control wiring. A thorough cleaning of the insulators and application of a hydrophobic coating to prevent future residue buildup resolved the issue. Even the shape of busbar supports matters: sharp edges on supports can create local electric field intensification, which amplifies EMI emissions in high-voltage systems.
Cable assemblies, both power cables and control cables, are another hotspot for EMI. Power cables carrying heavy currents generate magnetic fields, and if they’re run parallel to control cables in the same tray, inductive coupling will occur. The longer the parallel run, the stronger the coupling—we’ve seen issues when power and control cables are run together for more than 5 meters, even with minimal current difference. Shielded power cables can help, but only if the shield is properly grounded—if the shield is grounded at only one end, it can actually act as an antenna, picking up more EMI instead of blocking it. Control cables, on the other hand, are designed to be low-voltage and sensitive, so they’re especially vulnerable to EMI. Twisted pair control cables reduce coupling by cancel out magnetic fields, but if they’re routed too close to power cables, even twisted pairs can’t prevent interference. A rule we always share with clients is to maintain a minimum distance of 30cm between power cables (carrying over 100A) and control cables, or use separate trays with proper shielding.
Now, it’s important to separate EMI issues from other common switchgear problems, because misdiagnosis can lead to costly fixes. For example, a false relay trip could be caused by a loose connection, but if the trip only happens during peak load times (when busbar currents are highest), EMI is far more likely. Another red flag: glitches that only occur during switching operations (when breakers or contactors actuate) point to transient EMI from those components. Sensors that drift out of calibration without any obvious change in process conditions can often be traced to static magnetic fields from DC busbars. The key is to test for EMI systematically: use a field strength meter to measure electromagnetic levels near components during operation, check for ungrounded shields in cables, and verify clearance between power and control circuits. As a supplier, we always offer on-site testing support for clients who are trying to diagnose persistent issues—we carry portable EMI meters and can trace transients to their source in a matter of hours, instead of days.
But EMI issues aren’t just about fixing problems after they happen—they can be prevented during the design and installation phases, which is where good switchgear component selection comes in. For example, specifying busbars with larger separation between phases, or with embedded shielding layers, reduces magnetic field strength. Choosing circuit breakers with built-in transient suppression (like varistors or RC snubbers) cuts down on the high-frequency spikes they generate. For insulators, we recommend materials with high dielectric strength and low surface conductivity, especially for environments with dust or moisture. When it comes to cable assemblies, specifying shielded control cables with double-layer shielding for critical systems, and ensuring all shields are properly grounded at both ends, is a small step that prevents big issues later.

I’ll never forget the client who called us after three days of lost production—they’d tried three different electricians, none of whom could identify the problem, because they were focused on obvious issues like arcing instead of subtle EMI. That’s why I want every switchgear operator and project manager to know that EMI is a solvable problem, not an unavoidable risk. As a switchgear components supplier, we don’t just sell parts—we provide solutions to these kinds of real-world issues. If you’re dealing with intermittent glitches, false trips, or unexpected disruptions in your switchgear system, don’t spend hours troubleshooting on your own. Reach out to our team to discuss your specific challenges, and we’ll work with you to identify the source of the EMI and implement a cost-effective fix.
Switchgear References
- IEC 62271-1:2017, High-voltage switchgear and controlgear – Part 1: Common specifications
- IEEE Std. 1100-2005, IEEE Recommended Practice for Powering and Grounding Electronic Equipment
- Swami, M., and Gardner, R. (2019). Electromagnetic Compatibility in Power Systems. CRC Press.
- American National Standards Institute (ANSI) C119-2018, American National Standard for Electric Power Systems and Equipment – Voltage Ratings (60 Hertz)
- The Institute of Electrical and Electronics Engineers (IEEE) Transactions on Power Delivery, Volume 34, Issue 4, 2019, pp. 1892-1900: "Electromagnetic Interference from Low-Voltage Switchgear Components in Industrial Applications"